# NOx Sensor Failure Symptoms on Cummins & DAF Engines (P2200-P2203)
Short answer: A failing NOx sensor on a Cummins or DAF aftertreatment system usually announces itself with a check-engine lamp plus a derate, a fault code in the P2200–P2203 family or an SPN 3216 / 3226 with an FMI suffix, and a visible jump in DEF (AdBlue) consumption. Most of these trucks run two sensors — an inlet ahead of the SCR and an outlet behind it — and the most expensive mistake is replacing the wrong one. Confirm the fault with live NOx data and a connector inspection before you order parts.
What the NOx Sensor Does in a Cummins or DAF Aftertreatment System
The NOx sensor measures how much nitrogen oxide is left in the exhaust. On a Cummins ISX/X15, ISB6.7 or a DAF MX-11 / MX-13 with SCR, the ECM reads that value continuously to decide how much DEF the doser injects ahead of the catalyst. Too little and the truck blows through its NOx limit; too much and you pay for reagent you burn for nothing.
The sensor is not a simple resistance device. It is an amperometric ceramic element bundled with a heater and a control module that talks to the ECM over a digital link — which is why ohm-testing a NOx sensor in your hand tells you far less than it does on a temperature or pressure sensor.
The Two Sensors: Inlet vs Outlet — Which One Is Failing?
Almost every symptom conversation on these engines starts here, and getting it wrong is the number-one cause of a "new sensor, same fault" comeback.
- Inlet (upstream) sensor — mounted before the catalyst. It reports what the engine produced, and the ECM doses from that number, so a lazy inlet sensor makes the system under- or over-dose all day.
- Outlet (downstream) sensor — mounted after the catalyst. It reports what the SCR failed to convert, and the ECM compares the two readings to judge SCR efficiency.
In practice: a code for the inlet sensor points to the sensor, its wiring or the dosing calculation. A code for the outlet sensor points to the sensor, its wiring — or the catalyst, and a tired SCR will keep tripping outlet codes even after you fit a brand-new sensor. That is the failure mode that turns a one-part repair into three.
Symptoms of a Failing NOx Sensor
- Derate and a stop-engine warning. Most Cummins and DAF calibrations allow a limited number of drive cycles with an active aftertreatment fault before torque is cut and speed limited. Treat the first warning as your free diagnosis window.
- Rising DEF consumption. If the driver is filling the DEF tank twice as often with no change in route, the sensor reading is a prime suspect.
- Check-engine / MIL with P2200–P2203 codes. These OBD-II codes cover the sensor circuit itself: circuit fault, range/performance, low input and high input. On the J1939 side you will usually see SPN 3216 for the inlet sensor or SPN 3226 for the outlet sensor, each with an FMI suffix telling you whether it is a circuit, range or data-validity problem.
- Rough or choppy idle at low load, reported on lighter fitments such as the ISB6.7 when dosing hunts.
- Worse fuel economy — under-dosing and repeated correction both cost fuel.
- A failed opacity or emissions test, even when the dash shows nothing.
- A fault that clears itself and returns. Heater and connector faults are moisture-dependent, so codes that appear on cold, damp mornings and clear after a long run usually mean the sensor or its connector, not the catalyst.
One caution: a NOx reading that looks plausible but is wrong will not always set a code. If the truck is derating with an empty fault list, check live data before assuming the sensor is fine.
Common Causes of NOx Sensor Failure
- Soot, ash and urea crystallisation on the sensing tip. A doser that is misting badly, or an exhaust leak just upstream, will coat it.
- Water ingress at the connector. The most common electrical cause — look for green or white residue inside the plug and a swollen seal.
- A chafed or stretched harness. These sensors sit low on the frame rail or on the pipe itself, where debris and vibration do the rest.
- Heater failure from age and thermal cycling, not mileage alone.
- Contaminated oil or coolant in the exhaust, from a weeping turbo seal or a failing head gasket.
- The wrong sensor for the platform. 12 V and 24 V bodies are not interchangeable, and neither are the probe lengths used across Cummins and DAF applications — fitting a similar-looking sensor from another family just buys the same fault twice.
How to Diagnose a NOx Sensor Problem Step by Step
- Record the full code set first. Write down every SPN/FMI pair, the occurrence count and whether the fault is active or stored before clearing anything. Our Cummins SPN code lookup explains how to read them.
- Read live NOx data. Compare inlet and outlet values. An outlet reading that sits flat, holds a default or drops to zero while the inlet climbs is a sensor signature, not a catalyst one.
- Check power, ground and communication at the connector. Back-probe rather than pierce the insulation, and never bridge the pins with a test light — the heater current is high and the module is easy to kill.
- Inspect the connector and the harness run for water, corrosion, pushed-back terminals and chafe points.
- Pull the sensor and look at the tip. Light soot is normal; wet, crystalline or oil-black deposits mean something upstream caused the failure and must be fixed before the replacement goes in.
- Check the dosing side — a stuck or dribbling doser, a clogged DEF filter or out-of-spec DEF will destroy the next sensor the same way. Our diesel fuel system troubleshooting guide applies the same discipline on the fuel side of the engine.
- Fit, then re-read live data at operating temperature. A new sensor that reads plausibly but leaves the SCR efficiency monitor out of range is pointing at the catalyst.
What Mimics a Failed NOx Sensor
Before condemning the sensor, rule these out — each sets NOx-related faults and each is cheaper than a second sensor: a failed or clogged DEF doser injector or DEF filter; contaminated or diluted DEF; an exhaust leak between engine and SCR; a degraded SCR catalyst (the classic outlet-sensor trap); a DPF over-temperature event that damaged the heater; and wiring or connector faults in the aftertreatment harness.
Common Mistakes That Cause a Repeat Repair
- Replacing the outlet sensor when the code was for the inlet, or vice versa.
- Fitting a new sensor onto a truck with a dribbling doser.
- Reusing the old sealing washer, or greasing the probe itself instead of the thread only.
- Buying on price alone: on these platforms the inlet and outlet units look identical and often share an OEM prefix. Match on the OEM number and the voltage, not on appearance.
NOx Sensor Part Numbers for Cummins & DAF
Match on the number cast or printed on the unit you are removing. Fitments we supply include:
| Reference number | Application | Voltage |
|---|---|---|
| 3687930RX / 4326870 / 5WK9 6740B | Cummins 11.9 L / 15 L ISX15 (2013–2018) | 12 V |
| 4326874RX / 4326874 / 5WK9 6741B | Cummins Kenworth C500 / T660 | 12 V |
| 1954664PE / 4326872 / 2872942 | Cummins ISX | 12 V |
| 5WK9 6741 / 2872946 | Cummins 15.0 L / 11.0 L I6 | 12 V |
| 5WK9 6753 / 2872947 / 4326869 | Cummins ISB 6.7 L | 12 V |
| 2872948 / 5WK97462 | Cummins Dodge RAM 2500 / 3500 / 4500 6.7 L (2015–2017) | 12 V |
| 5WK97343B / A2C95849700-01 | DAF truck and Cummins ISX / MX11 11.9 L–15.0 L | 12 V |
| 2894940 / 5WK9 6675A | DAF and Cummins, Euro 5 | 12 V |
| 5WK9 6660C / 1810704 | Cummins and DAF | 12 V |
| 5WK96751A | DAF and Cummins truck | — |
| 2011648 / 5WK9 6619D | DAF heavy-duty truck | 24 V |
| 5WK9 6661D / 2006245 / 2006246 | DAF XF106, Euro 6 | 24 V |
| 2011649 / 5WK9 6628C | DAF CF85 / XF105 | 24 V |
| 1836060 / 5WK9 6628B | DAF truck | 24 V |
| 1836059 / 5WK9 6619C | DAF truck | 24 V |
| 2006246PE / 5WK96759C | DAF truck, 4-pin | 24 V |
| 2139930 / 4326769 / 5WK9 7348A | DAF truck (890 mm) and Cummins | 24 V |
Frequently Asked Questions
Can I drive with a failed NOx sensor?
Short distances, usually — but most Cummins and DAF calibrations escalate to a torque and speed derate after a set number of drive cycles with an active aftertreatment fault, and the SCR is being dosed blind in the meantime. Fix it inside the warning window.
How do I know if it is the inlet or the outlet sensor?
Read the code: SPN 3216 is the inlet sensor, SPN 3226 is the outlet. Then confirm with live data — an outlet sensor that reads flat or zero while the inlet rises is the sensor; an outlet reading that tracks the inlet under load usually means catalyst efficiency.
Will a new NOx sensor fix a P2200 code?
Only if the cause is the sensor or its circuit. P2200–P2203 are sensor-circuit codes, so a genuine sensor or connector failure is the most likely cause — but check power, ground and the connector first, because a chafed harness sets the same codes.
Do I need to replace both sensors at once?
Not as a rule. Replace the sensor the code identifies. On a high-mileage truck it is reasonable to plan for both, but replacing a healthy sensor instead of finding a dosing or catalyst fault just moves the problem.
Where to Buy the Right NOx Sensor
WDPART supplies replacement NOx sensors cross-referenced by OEM number for Cummins, DAF, Volvo, Scania and other platforms, so you can match the unit you are removing rather than ordering by vehicle description. Start from the NOx sensor collection or filter by brand: Cummins parts and DAF parts. Two fitments that cover a lot of mixed fleets are the 12 V NOx sensor for DAF truck and Cummins ISX / MX11 11.9 L–15.0 L and the 5WK9 6675A / 2894940 sensor for DAF and Cummins Euro 5. For Cummins ISX15 applications from 2013 to 2018 the direct reference is the 3687930RX / 4326870 / 5WK9 6740B unit, and 24 V DAF XF106 Euro 6 trucks take the 5WK9 6661D / 2006245 unit.
If the sensor turns out to be fine, the legacy guide to extending NOx sensor service life still holds up on cleaning and handling.
Bottom line: match the code to the right sensor, verify power and communication at the connector, and check the dosing side before you fit the replacement. On a Cummins or DAF truck the sensor is rarely the expensive part of the job — fitting a second one because the doser or the catalyst caused the first failure is.
*About WDPART: WDPART supplies OEM-spec replacement diesel, agricultural and construction equipment parts — NOx sensors, fuel filters and water separators, solenoids, radiators, injectors, diagnostic tools and more — with factory-direct pricing and a 1-year warranty.*