Description
Measuring range: -20°C - +150°C
Output mode: Three-wire system resistance output
standard: DIN EN 60751 (Corresponds to IEC751)
Screw thread: G1/2 standard pipe thread
Autothermal coefficient: 0.4K/mW (when the temperature is 0°C)
Long-term stability: R0 nominal resistance drift ≤0.04%
Anti-vibration level: At least 40g acceleration (10-2000Hz)
Insulation resistance: > 100MΩ, (when the temperature is 20°C)
Shock resistance level: At least 100g acceleration (after 8.5ms fluctuation)
Response time: Water @0.4m/s t0.5=0.05s t0.9=0.15s Air @2m/s t0.5=3.0s t0.9=10.0s
Test condition: 0.3mA-1mA
Temperature coefficient: TCR=3850ppm/K
Weight: 100g
Allowable tolerance: Class A
Measurement accuracy class: Class 0.25
Protection Class: IP65
Shell: stainless steel 304
Measurement medium: Fluid, such as liquid and gas.